CHEM 120L — Lab Exam Cram Sheet
Written, cumulative, in-person · Wed Dec 16, 2026, 12:30 PM · everything the lab exam can test, one page.
accurate measurement (analytical / volumetric)
approximate measurement (top-load / rough)
1 Lab techniques
- Analytical balance ±0.0001 g — draft-shielded room, vibration-proof table. Any mass that enters a calculation.
- Top-loading balance ±0.01 g — rough / excess-reagent weighing.
- Weighing by difference: weigh container+sample, dispense, re-weigh → mass = (before − after). Fewest weighings, several accurate masses.
- Quantitative transfer: rinse ALL residue into the receiving vessel — no analyte lost.
- Burette: rinse DI then titrant; no bubble in tip; read bottom of meniscus at eye level to ±0.02 mL; dropwise near endpoint.
- Pipette: volumetric (TD) = one fixed accurate volume (10.00 mL); Mohr = variable. Never blow out a TD pipette.
- Filtration: gravity (conical+paper, keep filtrate) vs vacuum (Büchner + filter flask, collect solid).
- Reflux = boil with condenser, no solvent loss. Bunsen: air open → hot blue; closed → cool yellow sooty.
Melting point = purity test: pure melts over a narrow range near the literature value; impure melts lower & broader. Lower end = first liquid; upper end = last solid melts.
2 Glassware & accuracy
- TD = "to deliver" (dispenses a volume): volumetric pipettes, Mohr pipettes, burettes. TC = "to contain" (holds a volume): volumetric flasks.
- Pick by required accuracy: precise → volumetric ware; rough → graduated cylinder / beaker. Use the least precise tool that still meets the need. Never heat volumetric glassware.
| Glassware | Type | Typical tolerance |
| 10 mL volumetric pipette | TD | ±0.02 mL |
| 25 mL volumetric pipette | TD | ±0.03 mL |
| 50 mL burette | TD | ±0.05 mL (read ±0.02) |
| 100 mL volumetric flask | TC | ±0.08 mL |
| Graduated cylinder | — | ~±1% |
| Griffin (low-form) beaker | — | ~±5% |
Griffin beaker = workhorse (50–1000 mL, borosilicate, heat/cold resistant). Berzelius (tall, 200 mL) = for a pH probe or thermometer (greater depth).
3 Significant figures & data
- Non-zero digits & captive zeros: significant. Leading zeros: not. Trailing zeros after a decimal: significant. Exact numbers: infinite.
- ×/÷ → keep fewest sig figs. +/− → keep fewest decimal places. Round at the end.
- Accuracy = closeness to true value (systematic error). Precision = reproducibility (random error). Can be precise but inaccurate.
- Error propagation: +/− → add absolute uncertainties; ×/÷ → add relative (%) uncertainties.
- Record to the tool's precision (e.g. 25.0 mL implies ±0.1 mL).
4 Safety & WHMIS 2015
- Eye protection = splash-proof safety goggles. Damaged signed-out item → replace immediately.
- Add acid to water, never water to acid.
- Fume hood = toxic fumes; snorkel = local point-exhaust (fumes/powder at the source).
- Locate: eyewash, first-aid kits, glass-waste bins, fire/first-aid/spill posters, exits. All glass → glass-waste bin.
- SDS (16 sections) = detailed hazard reference; supplier/workplace labels = short warnings.
- Pictograms: flame (flammable), flame-over-circle (oxidizer), gas cylinder, corrosion, skull (acute toxicity), health-hazard torso (carcinogen/organ), exclamation (irritant), exploding bomb, environment.
Exp 1 Reactions of Copper — the copper cycle
- Goal: carry Cu through a cycle and recover it → percent recovery. Cu wire accurately weighed (analytical) & sanded. DI water throughout.
- Cycle:
Cu → Cu(NO₃)₂ (HNO₃) → Cu(OH)₂ (NaOH) → CuO (heat ~10 min) → CuSO₄ (H₂SO₄) → Cu (excess Zn)
- Zn step: ~2.00 g ±0.01 g (top-loading, excess); displaces Cu, makes H₂. Snorkel handles the fine dry Cu powder (lung irritant). Rinse Cu with alcohol, cool on the bench, then weigh.
- What could go wrong: under-heated/insufficiently basic → gelatinous solid clogs the filter; wrong acid on CuO → start over; lost Cu → recovery <100%; not fully dry → apparent >100%.
Exp 2 Titration — identify an unknown solid acid
- Goal: find the unknown acid's molar mass → identify it. Primary standard = oxalic acid dihydrate (H₂C₂O₄·2H₂O), diluted to 100.00 mL ±0.08 mL (volumetric flask), used to standardize NaOH.
- Indicator = phenolphthalein (colourless → faint pink). Acid delivered by 10.00 mL volumetric pipette. Run ≥3 concordant trials.
- Unknown: 3 samples by weighing by difference, dissolve in DI water, titrate with the same NaOH.
molar mass = mass ÷ (mol NaOH ÷ protons)
- What could go wrong: using the rough mass for the standard; overshooting the endpoint (deep pink); mixing up trial labels.
Exp 3 Ion-Exchange Chromatography — quantify Cu²⁺
- Setup: cation-exchange column pre-saturated with H⁺ (HCl, rinsed to neutral). Glass wool holds beads in. Load 10.00 mL sample.
- Exchange: Cu²⁺ displaces H⁺ at 1 Cu²⁺ : 2 H⁺ (coloured band). DI water = mobile phase; rinse ≈ 5× sample volume to neutral eluate.
- Analyze: titrate eluate H⁺ with standardized ~0.1 M NaOH.
mol Cu²⁺ = ½ mol H⁺ → [Cu²⁺] = mol ÷ 0.01000 L
- Error logic (exam favourite): sites not fully H⁺-saturated → result too LOW; leftover unbound H⁺ not rinsed → result too HIGH.
Exp 4 Organic Synthesis of Acetaminophen
- Reaction:
p-aminophenol + acetic anhydride → acetaminophen + acetic acid, warm water bath (~70 °C — hot-plate readout ≠ bath temp). Use a powder funnel (wide neck).
- Purify: crystallize (key property = solubility) → vacuum-filter (Büchner), run vacuum +5 min to dry → recrystallize from DI water (dissolve hot, cool SLOWLY, don't stir — excess solvent lowers yield).
- Check purity: melting point on dry crystals, pure ≈ 168–172 °C (narrow); impure = low & broad. Compute percent yield.
Exp 5 Emission Spectra — identify by line spectrum
- Why: excited electrons drop to lower levels, emitting photons at characteristic wavelengths (
E = hc/λ) → a unique line "fingerprint." Match to reference spectra to identify.
| Ion | Flame | Ion | Flame |
| Li⁺ | crimson-red | Ca²⁺ | orange-red |
| Na⁺ | intense yellow (589 nm) | Sr²⁺ | scarlet |
| K⁺ | lilac/violet (cobalt glass) | Ba²⁺ | pale green |
| Cu²⁺ | green / blue-green | B | green |
View K⁺ through cobalt-blue glass to filter out the overpowering Na⁺ yellow. Noble gases → discharge tube + spectroscope.
★ Key calculations (drill these)
- Molar mass from titration:
mol NaOH = C×V; mol acid = mol NaOH ÷ protons; M = mass ÷ mol acid
- [Cu²⁺] from eluate:
mol H⁺ = C(NaOH)×V(NaOH); mol Cu²⁺ = ½ mol H⁺; [Cu²⁺] = mol ÷ V(sample, L)
- Standard concentration:
mol = mass ÷ M; C = mol ÷ V(L)
- Percent recovery / yield:
(actual ÷ theoretical) × 100
- Dilution:
C₁V₁ = C₂V₂
Private study aid for Zoe · not for use on graded work · built from the CHEM 120L LEARN materials.